Rolled Curved Panels & Flashing - 7/8" x 2.67" Corrugated

7/8" x 2.67" Corrugated Sample Photo

SIDING PROFILE
Siding Profile - 1 Corrugation Lap
1 CORRUGATION LAP
ROOFING PROFILE
Roofing Profile - 2 Corrugation Lap
2 CORRUGATION LAP
MATERIAL WT/SQ PLAIN RECOMMENDED ROOF LEAD SPAN TABLES
IN POUNDS PER SQ. FT. / 3 SPAN
FINISH
4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"
 ALUMINUM                       SMOOTH
MILL FINISH
STUCCO EMBOSSED PAINTED
 0.025 41.4 lbs 64 50 41 33 28 24 20 18 16 14 12
 0.032 55.2 lbs 84 66 54 41 37 32 27 24 21 18 16
 0.040 69.5 lbs 98 77 62 51 43 37 32 27 24 21 19
 0.063 109.5 lbs 147 116 93 77 65 56 48 41 36 32 29
 0.080 139.0 lbs 164 129 104 86 73 62 54 46 40 36 32
                         
 GALVANIZED STEEL                       GALV.
BRIGHT
SPANGLE
SILICONE
POLYESTER
COATED
KYNAR
 24 guage 141.5 lbs 92 72 59 49 41 35 30 26 23 20 18
 22 guage 172.1 lbs 113 90 72 60 50 43 37 32 28 25 22
 20 guage 202.7 lbs 136 107 87 72 60 51 44 38 34 30 27
 18 guage 263.9 lbs 172 136 110 91 76 65 56 49 43 38 34
 16 guage 330.0 lbs 217 171 139 115 96 82 71 62 54 48 43
                         
 ALUMINIZED STEEL                       MATTE GRAY
 24 guage 132.7 lbs 81 63 52 43 36 31 26 23 20 18 16
 22 guage 163.3 lbs 99 79 63 53 44 38 32 28 25 22 19
 20 guage 193.9 lbs 119 94 76 63 53 45 39 33 30 26 24
                         
 STAINLESS STEEL                       A.I.S.I No. 2B
COLD ROLLED
REFLECTIVE
 26 guage 95.3 lbs 72 57 46 38 32 27 23 20 18 16 14
 24 guage 122.9 lbs 92 73 59 49 41 35 29 26 23 20 18
 22 guage 153.6 lbs 113 90 72 60 50 43 36 32 28 25 22
                         
NOTES  1. Allowable loads shown are based on stress governing per latest A.I.S.I specification.
 2. Allowable loads shown may be increased by 1/3 for wind loading.
 3. Applications of this product on roofs with a pitch of less than 12° are not recommended.
 