SIDING PROFILE

1 CORRUGATION LAP |
ROOFING PROFILE

2 CORRUGATION LAP |
| MATERIAL |
WT/SQ PLAIN |
RECOMMENDED ROOF LEAD SPAN TABLES
IN POUNDS PER SQ. FT. / 3 SPAN |
FINISH |
| 4'-0" |
4'-6" |
5'-0" |
5'-6" |
6'-0" |
6'-6" |
7'-0" |
7'-6" |
8'-0" |
8'-6" |
9'-0" |
| ALUMINUM |
|
|
|
|
|
|
|
|
|
|
|
SMOOTH
MILL FINISH
STUCCO EMBOSSED PAINTED |
| 0.025 |
41.4 lbs |
64 |
50 |
41 |
33 |
28 |
24 |
20 |
18 |
16 |
14 |
12 |
| 0.032 |
55.2 lbs |
84 |
66 |
54 |
41 |
37 |
32 |
27 |
24 |
21 |
18 |
16 |
| 0.040 |
69.5 lbs |
98 |
77 |
62 |
51 |
43 |
37 |
32 |
27 |
24 |
21 |
19 |
| 0.063 |
109.5 lbs |
147 |
116 |
93 |
77 |
65 |
56 |
48 |
41 |
36 |
32 |
29 |
| 0.080 |
139.0 lbs |
164 |
129 |
104 |
86 |
73 |
62 |
54 |
46 |
40 |
36 |
32 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| GALVANIZED STEEL |
|
|
|
|
|
|
|
|
|
|
|
GALV.
BRIGHT
SPANGLE
SILICONE
POLYESTER
COATED
KYNAR |
| 24 guage |
141.5 lbs |
92 |
72 |
59 |
49 |
41 |
35 |
30 |
26 |
23 |
20 |
18 |
| 22 guage |
172.1 lbs |
113 |
90 |
72 |
60 |
50 |
43 |
37 |
32 |
28 |
25 |
22 |
| 20 guage |
202.7 lbs |
136 |
107 |
87 |
72 |
60 |
51 |
44 |
38 |
34 |
30 |
27 |
| 18 guage |
263.9 lbs |
172 |
136 |
110 |
91 |
76 |
65 |
56 |
49 |
43 |
38 |
34 |
| 16 guage |
330.0 lbs |
217 |
171 |
139 |
115 |
96 |
82 |
71 |
62 |
54 |
48 |
43 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ALUMINIZED STEEL |
|
|
|
|
|
|
|
|
|
|
|
MATTE GRAY |
| 24 guage |
132.7 lbs |
81 |
63 |
52 |
43 |
36 |
31 |
26 |
23 |
20 |
18 |
16 |
| 22 guage |
163.3 lbs |
99 |
79 |
63 |
53 |
44 |
38 |
32 |
28 |
25 |
22 |
19 |
| 20 guage |
193.9 lbs |
119 |
94 |
76 |
63 |
53 |
45 |
39 |
33 |
30 |
26 |
24 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| STAINLESS STEEL |
|
|
|
|
|
|
|
|
|
|
|
A.I.S.I No. 2B
COLD ROLLED
REFLECTIVE |
| 26 guage |
95.3 lbs |
72 |
57 |
46 |
38 |
32 |
27 |
23 |
20 |
18 |
16 |
14 |
| 24 guage |
122.9 lbs |
92 |
73 |
59 |
49 |
41 |
35 |
29 |
26 |
23 |
20 |
18 |
| 22 guage |
153.6 lbs |
113 |
90 |
72 |
60 |
50 |
43 |
36 |
32 |
28 |
25 |
22 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| NOTES |
1. Allowable loads shown are based on stress governing per latest A.I.S.I specification.
2. Allowable loads shown may be increased by 1/3 for wind loading.
3. Applications of this product on roofs with a pitch of less than 12° are not recommended. |