RPS Engineering Incorporated Conveyor Covers Architectural Siding & Roofing
Fiberglass Domes Flat Tank Covers
Launder & Channel Covers Aluminum Domes
Home About RPS Contact Us
 

Architectural Siding & Roofing

Architectural Roofing - Structural Standing Seam

Structural Standing Seam Sample Photo
 
 
Structural Standing Seam Profile
 
 
SEAM WITH CLIPS BEFORE SEAMING

SEAM WITH CLIPS AFTER SEAMING
 
 

ALLOWABLE WIND UPLIFT LOADS (PSF)

Material Gage Width Span
3'-0" 3'-6" 4'-0" 4-6" 5'-0"
STEEL 24 12" 53 53 53 53 53
STEEL 24 18" 35 35 35 35 35
STEEL 22 12" 70 70 70 70 70
STEEL 22 18" 47 47 47 47 47
Notes:
1.  Allowable loads shown are based on 1980 edition of AISI
     specifications.
2.  Deflection is limited to L/240 of span.
3.  Loads are based on spans of 3 or more.
4.  FY = 50 ksi for steel panels.
5. Uplift values based on attachment to 16 ga. purlins with
     2 - #10-16 x 1" SD ST screws.

TEST REPORT SUMMARIES

AIR INFILTRATION:  had 0.01 cfm / SF leakage with 15 psf pressure differential per ASTM E 283.

WATER RESISTANCE:  No water penetration under 5 gallon per hour spray at 6.24 psf pressure differential per ASTM E 331.

UL90 UPLIFT RATING:  16" wide, 24 ga. steel panels with clips installed over 16 ga. purlins (40 ksi steel) and spaced maximum of 5'-0" O.C. with one screw per clip.  Insulation varies with Construction No.  (Construction No. 90, 176, and 180.)

UL90 UPLIFT RATING:  16" wide, 24 ga. steel panels with clips spaced a maximum of 48" O.C. over rigid insulation (min. 1" thickand 2.0 pcf) over 22 ga. steel deck (33ksi) with one #11 x 3 ¾" long self-drilling screw with Phillips drive and flat head per clip and bearing plate under each clip.  Bearing plate is 0.050" x 3" x 3.25".  (Construction No. 238.)

UL90 UPLIFT RATING:  16" wide, 24 ga. steel panels with clips spaced a maximum of 2'-0" O.C. installed over ½" plywood deck with two #12-14 x 1" pancake head screws per clip.  (Construction No. 548.)

UL90 UPLIFT RATING:  16" wide, 24 ga. steel panels with clips spaced a maximum of 5'-0" O.C. installed over 5/8" plywood deck with two #10 x 1" pancake head screws per clip.  (Construction No. 549.)  Fabral recommends a maximum clip spacing of 2'-0" O.C. for installations over plywood.

 

 

Click here for Curved Flashing Details

 


Curving Structural Standing Seam Panels

RPS Engineering has the ability to curve
2" Structural Standing Seam Panels in
widths varying from 12" to 24" wide.
The machine is portable and can be shipped
to job sites across the country.
     
  Call, fax or e-mail your inquires today!